Most Effective Ways to Overcome Diesel Generator’s Problem

Overcome Diesel Generator’s Problem: Diesel generators are not only a significant investment but also an outstanding asset. Because this is a machine, there will be some problems later. We can overlook some of these problems by routine maintenance, but cannot treat every issue similarly.

When your diesel generator turns terrible, you still need to have a solution. Generators can be lifesavers – workers who support your company in the event of a prolonged power outage.

For houses too, they will aid you with the power in case of frequent blackouts. However, they are not as perfect as valuable as they are. The GENERATOR can sometimes be damaged.

It is essential to know how to repair your generator effectively so that you will not have problems when you most need a backup resource. In this article, we have tried to address such issues with a solution to them. So, you can make the efficient out of your generators without adding up much to the costs.

Discussing below some of the issues:

# Leaks:

Leaks are also a common generator problem. There are three common types of leakage. Fuel, coolant, and lubricant.

Each of these leaks can have many adverse effects on the operation of your diesel generator.

There are various reasons behind a leak- high temperatures and wet build-up, among others. If you wish to avoid leakages, the most efficient way is a regular check-up and clean up.

To begin with, you must replace the hoses after two years. You can make changes earlier than specified as well, depending on how often and how much you use the machine.

Therefore it is advisable to carry out routine maintenance checks at regular intervals. Damage to the seal can also cause leakage. Sometimes a leak can occur, and you cannot do anything about it because of a malfunctioning fuel. These sensors can stick and thus keep you out of danger. It is best to check the fuel level manually.

# Overheating:

Several diesel generators heat up with long-term use. However, if you see an unusual temperature rise, you have to do something. Overheating is often the result of low cooling levels. Therefore you must check this. When the cooler is down, please refill it. You should also always check the concentration of coolant, lubricant, and fuel before starting the generator.

Most people just check the fuel level without knowing that the other two are equally crucial for the functioning of the diesel generator. Leakages can also cause low cooling levels.

# High Fuel Level Alarms:

Does your alarm ring often? You might worry that something is wrong? Well, you shouldn’t. An increased fuel consumption alarm is a standard protocol installed on most generators to indicate that the tank is almost full. The signal is activated when the fuel level exceeds 95%.

See Also: Tech Blog

But in some cases, the bell also rings due to rising temperatures. The alarm activates due to fuel expansion. It can even happen on sunny days. You can turn off the alarm or reset it manually.

# Wet Stacking:

The accumulation of unburnt fuel in the exhaust system is known as wet stacking. Several reasons lead to it. Damp build-up can also occur due to stress for a long time. As a result, the engine has to run at the required temperature. The signs of moist regulation cause the presence of bluish oil. If you also notice that lubricating oil is overused, this also indicates a wet pile. In order to avoid wet stacking, we recommend you to start a diesel generator with at least ¾ load. The result can reach the required temperature and burn the fuel completely.

# Burning of Excess Fuel:

Buring of fuel is a problem with diesel generators that can cause big bumps in your pocket. Generators that burn more fuel attend to cause issues that must be met as soon as possible.

But how do you know that your generator burns excess fuel? Black soot smoke is an indication. It can occur when the tip of the injector is worn. The worn nozzle is responsible for fuel in the cylinder, even when the generator is idle. To fix this problem, you need to replace the worn injector tip.

Overcome Diesel Generator’s Problem | Some Basic Problem and Their Solutions:-

1. Low coolant level:

The generator can set the alarm or turn it off when the coolant level is low. Most generators do not have the ability to detect low coolant levels. Conversely, an alarm usually sounds when the temperature of the coolant rises. If you hear that sound, add more coolant when the level is low. If it still does not stops, you may need to dig deeper to look for leaks.

2. Block heater:

The function of a block heater is to heat the coolant that flows around the engine block. This process can prevent oil from thickening in cold temperatures. Contrary to misunderstanding, heating blocks are also essential in warm climates.

3. Control is not automatic:

The generator has an equalizer or control panel with which the operator can adjust the settings. The dashboard shows vital information about the engine and alternator. The operators make most of the operator panel service calls, who do not activate automatic control.

4. Generator not starting:

New generators often go through this problem. The combustion system already has a higher tolerance due to stricter and more airtight emission requirements.

It can affect the generator’s ability to start. If an older generator fails to start, it is often due to a leaky line or a check valve that does not hold fuel properly.

5. No fuel:

Sometimes the display doesn’t work correctly. Hold the meter in a position that shows that there is still a lot of fuel, even though it is almost empty.

Conclusion: Overcome Diesel Generator’s Problem

There are a lot of troubles in perfectly handling power Generators. The best way to manage these little things is by keeping a regular check and doing regular clean-up of the machine.

If you find out the issues in time, take prompt action immediately. This will save your money, and you will not need to spend more than necessary of the maintenance!